Issue
Error message "Sensor is invalid" is displayed on the control box.
Answer/Cause
1) IMU adjustment is not completed.
2) The cylinder reset is not completed.
Explanation/How to deal
1) Check the error message on the machine monitor.
- Error message on the machine monitor:DK80KM
(Angle sensor (IMU) 1 + operation error / setting error)
- Execute IMU adjustment and confirm if the problem would be resolved
- Machine monitor error message: DKTEMB
(Boom stroke reset encoder Z + functional decline)
This message appears when the reset has not been applied for more than a certain period of time, such as in clearance work (work in which the cylinder is not moved to the end).
- Please check if the problem would be resolved by resetting the cylinder.
If the problem persists, on-site diagnosis is required.
The sensor may have a poor contact, disconnection, or abnormality.
Please check the KOMTRAX error and diagnose the problem onsite according to the store manual.
Comments
0 comments